Over the last
decade EURADOS, through its Working
Group 2 (WG2), has been carrying out a programme of work on harmonization
of individual monitoring in Europe. WG2
Subgroup 2 was established specifically to carry out a feasibility study
for a programme of self sustained IMS intercomparisons in Europe with
the aims of
improving the harmonization of individual monitoring and helping
the IMS to comply with ISO 17025. Following the feasibility study,
EURADOS established an Organization Group to start the programme.
The 2008
intercomparison for whole body dosemeters and the 2009
intercomparison for extremity dosemeters have been completed. EURADOS
now has the pleasure of announcing the 2010 intercomparison for whole
body dosemeters.
Scope
The 2010 intercomparison is for whole body dosemeters used for the assessment of Hp(10) and/or Hp(0,07).
Irradiations, restricted to photons, will be carried out in an accredited or primary standard European irradiation facility in terms of Hp(10) and Hp(0,07) in the following ranges:
1. Energy: 30 keV to 1,3 MeV
2. Dose: 0,2 mSv to 1 Sv
3. Angle of incidence: ± 60º
Intercomparison
procedure
IMS
wishing to participate will complete the application form which can be
downloaded HERE.
The coordinating laboratory will register each application and inform
each participating IMS when their application has been accepted.
On
acceptance of the application, the participants will receive an invoice
from EURADOS and instructions for dosemeter labelling and dispatch.
The
participation fee is 1250 Euro per dosimetry system. EURADOS sponsors
will pay 1125 Euro for one system and 1250 Euro for any additional
systems.
Fees must be transferred in advance to the EURADOS bank account
(free of bank transfer costs) after receiving the invoice from EURADOS.
Refunding will only be possible in the unlikely event that the
intercomparison is cancelled by EURADOS.
The fees
have been calculated on a non-profit base and any surplus money will be
used to support the harmonization of individual monitoring and
maintaining expertise in this field within EURADOS.
For
this intercomparison a total of 26 dosemeters are required from each
participant.
1. 20 dosemeters for irradiation
2. 4 transit dosemeters for background control
3. 2 spare dosemeters
After
the irradiations have been carried out, the coordinating laboratory will
return the dosemeters to the participants for readout. Within one month
from receiving the dosemeters the participants will send the results in
terms of Hp(10) and/or Hp(0,07) to the
coordinating laboratory. All results must be sent on the form supplied
by the coordinating laboratory.
After
the deadline to submit results to the coordinating laboratory,
participants will be sent the irradiation
data and their response values. Change of results after distribution of
the irradiation data will only be possible in case of technical or
administrative errors made by the irradiation laboratory or the
coordinating laboratory.
After
confirmation of the results, EURADOS will provide the participants with
a “Certificate of Participation” including information on the
irradiation qualities, doses, response values and overall uncertainties
for all irradiations.
Intercomparison
report
The
Organization Group will prepare a report summarizing the results of the
intercomparison. The report will include the names of the IMS that have
participated and the types of dosemeter used but the results will be
presented anonymously.
Intercomparison
results will be treated by EURADOS as confidential data and IMS identity
will not be disclosed. Data
used in technical and scientific studies will be anonymous. The
Organization Group has agreed to ensure confidentiality and the
participants results will be known only to a minimum number of persons
within the Organization Group (OG).
| Provisional Schedule – dates to be confirmed | |
|
May
2010 |
Announcement
- Call for participants |
|
30
July 2010 |
Deadline
for IMS sending Application Forms |
|
6
August 2010 |
Deadline
for IMS confirmation and receiving guidelines |
|
3
September 2010 |
Deadline
for IMS sending dosemeters to OG |
|
October
2010 |
Irradiation |
|
November
2010 |
IMS
Receiving dosemeters for readout |
|
December
2010 |
IMS
sending dosemeters results to OG |
|
January
2011 |
OG
sending and confirming results from IMS |
|
January
2011 |
IMS
receiving Certificates of Participation |
| EURADOS Intercomparison 2010 Organization Group | |
| Andrew McWhan | VT Group, UK (Coordinator) |
| Elena Fantuzzi | ENEA, IT |
| Markus Figel | Helmholtz-Zentrum
Muenchen, D |
| Tom Grimbergen | NRG, NL |
| Ana M. Romero | Ciemat,
E |
| Hannes Stadtmann | Seibersdorf Laboratories, AT |
| Contact: eurados.intercomparison2010@webcdrs.co.uk | |